Power
up system and "Pur" is displayed on topside panel for 30 seconds while
in purge mode. Regular operation will then assume.
Press
Heat and Light key until " r--" appears." r--" is the
revision level of the system that is being programmed. This is for system ID and
is not adjustable. This revision level may change as additions or changes are
made to the system.
Press
Heat key again and C or F will appear. Press Jets One key to toggle from C to F.
Celsius or Fahrenheit. When choice is made press Heat key to go to next mode.
C
2,4,5,6,7, or 12 will appear. Press Jets One key to change the value for
filtration cycle within a 12-hour period. Circ pump systems should be set to
C12. Press Heat Key to go to next mode.
HC
( High Current ), LC ( Low Current ), or 230 will appear. Press Jets one key to
toggle from HC, LC or 230 operation. HC operation allows heat capability at any
time where LC operation will drop out the heater if Pump 1 high speed, Pump 2
low or high speed, or the blower is activated. Pump 1 hi speed and Pump 2 will
be able to run at the same time with no heat. Pump 1 and or Pump 2 will override
the blower in this set up.
230
is for European configuration that runs the equipment in combinations that allow
a minimum amperage draw. Press Heat Key to go to next mode.
100
to 106 or 38 to 41 will appear depending on the Celsius or Farenheight set up.
Press Jets One key to change value for maximum temperature set capability for
regular use. 104 is recommended.
When choice is made press Heat Key to go to next mode.
P
11, P12 or P10 will appear. Press Jets One to set pump operation. P 11 = Pump 1
single speed. P12 = Pump 1 two speed. P10 = Pump 1 Two speed, low, high, off and
is for two speed primary pump operation while using a circ pump. When choice is
made press Heat key to go to next mode. Do
not run P12 if using circ pump
P
21 or P 22 will appear. Press Jets One key to toggle between 1 or 2 to set pump
operation. P 21 = Pump 2 single speed. P 22 = Pump 2 two speed. When choice is
made press Heat Key to go to next mode.
P
6 or P 12 will appear. Press Jets One key to toggle between P 6 or P12 to set
the system purge time. P 6 = Purge every 6 hrs. P 12 = Purge every 12 hrs. Press
heat key to go back to run mode to
lock in new program, otherwise it will default to previous setting.
THESE
PROGRAMMING INSTRUCTIONS ARE FOR THE INSTALLER OF THE SPA PAK AND SHOULD NOT BE
ISSUED TO THE END USER.
|