Power
up system and " Pur" will appear for 30 seconds while system is in
purge mode and then normal operation will assume. The temperature setting
will assume the previous value.
|
|
It
may be necessary to bleed excess air from heater body prevent overheating of
heater on start up. See spa operating Instruction for procedure to bleed
air.
|
|
Press
Jets One Key to activate Pump One. Shuts off automatically in 30 min.
|
|
Some
models have the ability to set run time from 10 – 30 minutes. This can be
done by holding down the jets key when activating
|
|
Press
Light Key to activate light on/off. Push and hold will dim light
|
|
Press
Heater Key to adjust temperature. Press once and hold will raise
temperature. Press a second time and hold will lower the temperature to the
minimum set point of 70 F or 21C. A red LED will flash at the topside
control while there is a call for heat. Some models have a separate heat up
and heat down key.
|
|
Press Blower Key to activate blower on/off. Press and hold to vary
speed
|
|
Press Jets Two Key to activate pump 2.
|
|
Auxiliary
key if for added on/off option. This function will shut off automatically in
12 hours if left on.
|
|
Press
Invert Key to flip the digital readout 180 degrees.
|
|
Press
Heat Key and Pump 1 Key simultaneously to activate temperature LOC and the
same do de-activate.
|
|
If
the tub temperature reaches 112 F the control will flash " OH
"with the temperature, and shut the system down until the temperature
drops below 112F. If the heater body temperature reaches 112 F, the control
will flash " hot " and the system will shut down. When it drops
below 112 F it will automatically turn back on. There is a third level of
protection via a two pole relay that will trip at 118 F. If this trips, the
readout at the topside control will read "HL" ( HIGH LIMIT )and
the tub must cool to less than 112F. This hi limit trip can be manually
reset by pressing the heat key of the control pad. If this trips repeatedly,
call your dealer for service.
|